HP ProCurve Switch 3500yl-24G-PWR Intelligent Edge J8692A HP ProCurve 3500yl-24G-PoE+ Switch J9310A. IEEE 802.1s Multiple Spanning Tree Protocol: provides high. .Implementation of Spanning-Tree Protocol on Procurve switches lacks elements that provide faster failover and greater redundancy— features such as PVST+, BackboneFast, and CrossStack UplinkFast.
BPDU protection is a security feature designed to protect the active STP topology by preventing spoofed BPDU packets from entering the STP domain. In a typical implementation, BPDU protection would be applied to edge ports connected to end user devices that do not run STP. If STP BPDU packets are received on a protected port, the feature will disable that port and alert the network manager via an SNMP trap as shown in BPDU protection enabled at the network edge.
BPDU protection enabled at the network edge
The following commands allow you to configure BPDU protection on VLANs for which the port is a member.
Syntax:
[no] spanning-tree
bpdu-protection
Enables/disables the BPDU protection feature on a port.
Default: Disabled.
Syntax:
[no] spanning-tree
bpdu-protection-timeout
Configures the duration of time when protected ports receiving unauthorized BPDUs will remain disabled. The default value of 0 (zero) sets an infinite timeout (that is, ports that are disabled by bpdu-protection
are not, by default, re-enabled automatically).
Default: 0
Range: 0 - 65535 seconds
For an example of using this command, see Re-enabling a port blocked by BPDU protection.
BPDU protection is a security feature designed to protect the active STP topology by preventing spoofed BPDU packets from entering the STP domain. In a typical implementation, BPDU protection would be applied to edge ports connected to end user devices that do not run STP. If STP BPDU packets are received on a protected port, the feature will disable that port and alert the network manager via an SNMP trap as shown in BPDU protection enabled at the network edge.
BPDU protection enabled at the network edge
The following commands allow you to configure BPDU protection on VLANs for which the port is a member.
Syntax:
[no] spanning-tree
bpdu-protection
Enables/disables the BPDU protection feature on a port.
Default: Disabled.
Syntax:
[no] spanning-tree
bpdu-protection-timeout
Configures the duration of time when protected ports receiving unauthorized BPDUs will remain disabled. The default value of 0 (zero) sets an infinite timeout (that is, ports that are disabled by bpdu-protection
are not, by default, re-enabled automatically).
Default: 0
Range: 0 - 65535 seconds
For an example of using this command, see Re-enabling a port blocked by BPDU protection.
Syntax:
Enables/disables the sending of errant BPDU traps.
CAUTION: This command should only be used to guard edge ports that are not expected to participate in STP operations. Once BPDU protection is enabled, it will disable the port as soon as any BPDU packet is received on that interface. |
Syntax:
Hp Procurve Switches
show spanning-tree bpdu-protection
Displays a summary listing of ports with BPDU protection enabled. To display detailed per-port status information, enter the specific port number(s). BPDU protected ports are displayed as separate entries of the spanning tree category within the configuration file.
Displaying BPDU protection status for specific ports
Hp Procurve Switch Firmware
Ports disabled by BPDU Protection remain disabled unless BPDU Protection is removed from the switch or by configuring a nonzero BPDU protection timeout. For example, if you want to re-enable protected ports 60 seconds after receiving a BPDU, you would use this command:
Related Supplies, Accessories, & Products
Spanning Tree Portfast Hp Procurve
more Product Information in pdf format
Spanning Tree Priority Hp Procurve
summary | |||||||||||||||||||||||||||
The HP Procurve managed 24-port switch has 10/100BASE-TX autosensing per port and 2 open transceiver slots for media flexibility. The HP Procurve switch 2524 is ideal for low-cost, managed 10/100 connectivity with uplinks. | |||||||||||||||||||||||||||
features | |||||||||||||||||||||||||||
| |||||||||||||||||||||||||||
| |||||||||||||||||||||||||||
All brand and product names are trademarks of their respective companies. Technical information in this document is subject to change without notice. |